PCT513 Wi-Fi touchscreen thermostat in an angled white-background shot, red screen reading 72 with Heat to 76

PCT513

Wi-Fi Touchscreen Thermostat

Wi-Fi touchscreen thermostat for 2H/2C conventional or 4H/2C heat pump systems, supporting up to 16 remote zone sensors and geofencing.

Overview

The Wi-Fi Touchscreen thermostat makes it easier and smarter to control your household temperature. With remote zone sensors, you can balance hot or cold spots throughout the home to achieve best comfort. And you will be able to remotely control the temperature anytime through your mobile phone and web portal.

Key Features

  • 4.3-inch colour touchscreen, 480 × 272
  • Supports 2H/2C multistage conventional system or 4H/2C Heat Pump system, plus dual fuel
  • Up to 16 remote zone sensors on 915 MHz, each rated ±0.5 °C
  • PIR occupancy sensor, 3 m / 70° range
  • Geofencing, vacation mode and a 5-day weather forecast on the main screen
  • Voice control through Amazon Alexa and Google Home
  • 7-day scheduling with 4 periods per day
  • Fan circulation mode, which runs the fan at set intervals
  • Filter reminder and abnormal-temperature alert
  • Remote control via mobile phone and web portal

Display and sensing

The front panel is a 4.3-inch colour touchscreen at 480 × 272. Behind it the thermostat measures temperature, humidity and motion.

MeasurementRating
Thermostat temperature accuracy±1 °C
Remote sensor temperature accuracy±0.5 °C
Humidity sensor±3 % (20–80 % RH)
OccupancyPIR, 3 m / 70°
Auto-changeover deadband1.5 °C / 3 °F

A room with a remote sensor is measured more accurately than the room the thermostat is mounted in: ±0.5 °C against ±1 °C.

Comfort and automation

Occupancy and remote sensors. With up to 16 sensors on 915 MHz, the thermostat can work from the average of the rooms that recently detected motion, or from one room you select. Sensors do not remove the temperature difference between rooms; they decide which room the thermostat follows.

Geofencing. The thermostat can switch to an away setpoint when the last phone leaves the geofence and return to the home setpoint when the first one comes back.

Vacation mode. Set a departure and return date, plus the temperature band to hold while you are away.

Weather. The main screen shows the current day and the next four days.

Fan circulation. The fan can run at set intervals to even out air temperature without calling for heating or cooling.

Scheduling. 7-day programming with four periods per day — the thermostat follows a fixed period structure rather than an editable number of periods.

Alerts and installation

  • Filter reminder — a service reminder on the thermostat when the filter is due.
  • Abnormal temperature alert — triggered when the room drops about 4.8 °C (roughly 10 °F) within two hours, which usually means the heating has failed.
  • Device test — each output can be exercised during installation to confirm the wiring before the thermostat is handed over.

Terminals

TerminalFunction
RH / RC24 VAC power, heating and cooling transformer
CCommon — required unless the SWB511 adapter is used
W1 / W2First and second stage heating
Y1 / Y2First and second stage cooling
GFan
O/BHeat pump changeover valve
SOptional module terminal — combines Y and G onto one conductor

No C-wire installations

If you have R, Y, and G wires, you can use the C wire adapter (SWB511) to supply power to the thermostat when there is no C wire. If the wall also has W, connect it as well — that keeps the second heating stage.

Not supported

Two-wire systems, fan coil units, multi-speed fans, ERV/HRV/VRV systems, baseboard heaters and 3-stage conventional heating. Systems running at 120 V or higher, or with thick wires joined by wire nuts, are also not compatible.

Specifications

Wi-FiWi-Fi 2.4GHz
Compatible Systems2H/2C multistage conventional; 4H/2C heat pump
Remote SensorsUp to 16 remote zone sensors (915MHz), ±0.5 °C accuracy
GeofencingGeofencing
Motion DetectionPIR occupancy sensor, 3 m / 70°
C-WireC-wire required; SWB511 adapter for no-C-wire installations

Key Benefits

16 Remote Zone Sensors

915MHz remote sensors balance hot and cold spots across large spaces.

Geofencing

Auto-adjusts temperature based on your location.

North America 24VAC

2H/2C conventional and 4H/2C heat pump support.

No-C-Wire Adapter

Works with SWB511 adapter when there is no C-wire.

Ideal For

Common deployment scenarios where Wi-Fi Touchscreen Thermostat delivers the most value.

North American Homes

2H/2C conventional and 4H/2C heat pump systems on 24VAC.

Large Homes & Offices

Up to 16 remote zone sensors balance hot/cold spots.

Hotel Multi-Unit Management

MQTT/cloud API for BMS and property management integration.

Smart Energy Management

Geofencing and schedules optimize heating and cooling.

No-C-Wire Retrofits

SWB511 adapter powers the thermostat from R/Y/G wires.

OEM / ODM Projects

OEM branding and ODM development available.

Frequently Asked Questions

Does PCT513 work with North American HVAC systems?
Yes, it supports North American 24VAC systems: 2H/2C conventional (gas/electric/oil) and 4H/2C heat pumps, plus dual-fuel setups.
Need a C-Wire? What if my building does not have one?
If you have R, Y, and G wires, you can use the C wire adapter (SWB511) to supply power to the thermostat when there is no C wire.
Can we manage multiple units (e.g., hotel) from one platform?
It supports MQTT/cloud API for seamless integration with North American BMS tools.
Can the PCT513 work with a thermostat remote sensor?
Yes. Up to 16 remote zone sensors use 915MHz communication to measure room temperature and detect occupancy, balancing hot/cold spots across large spaces (e.g., offices, hotels).
Which voice assistants does it support?
Amazon Alexa and Google Home. Both are listed in the datasheet, so you can change setpoints and modes by voice as well as from the app and the web portal.
How accurate is the temperature reading?
The thermostat's own sensor is rated ±1 °C. Remote zone sensors are rated ±0.5 °C, so a room with a sensor is measured more accurately than the room the thermostat is mounted in.
What does the S terminal do?
S is an optional module terminal. Wiring it lets Y and G share one conductor, which frees a wire in the wall for installations that need one more conductor.
Which systems are not supported?
Two-wire systems, fan coil units, multi-speed fans, ERV/HRV/VRV systems, baseboard heaters, 3-stage conventional heating, and any system running at 120 V or higher or using thick wires joined with wire nuts.

Related Products

Interested in Wi-Fi Touchscreen Thermostat?

Download the datasheet or request pricing — our team will respond within 24 hours.

Our engineers usually reply within one business day.